QC Inspection Services Ltd. Vol. 3, #3
NEWSLETTER

Did you know . . . ASME has now included these Canadian Structural Steel materials, CSA G40.21 Grade 300 and 350 steel as P1, e.g., 300W (44W) & 350W (50W). There is no longer a need to develop special Welding Procedure Specification (WPS) using these materials as your regular P1 WPSs are now acceptable. QC Inspection Services would be pleased to discuss these changes with our clients and perform the necessary revisions.

ALERT - Building Owners, Engineers & Architects.

CSA W47.1 states, "It is the responsibility of the purchaser to ensure, through adequate inspection, that the required structural steel fabrication and erection quality of building structures is attained."

This is typically achieved through third party inspections done by inspection companies certified by the Canadian Welding Bureau to CSA W178.

QC Inspection Services is certified by the Canadian Welding Bureau for third party structural steel inspections. We would be pleased to discuss our qualifications and how we can best serve your third party inspection needs.

At QCI . . . Congratulations to:

Walter Bonnell, Technologist in Training, who has received his CGSB G48.9712 Level II Magnetic Particle Testing Certification.